What to do if the ringer stops working while using your V®500 Connect.

 

If you notice that the ringer stops working when using the V®500 Connect, you will need to run a test on your devices. To do so, you'll need to place the outdoor panel next to the monitor.

To connect it, you can use two 0.5mm² diameter wires. A short length is sufficient for this test (less than one meter).

 

If the ringing is restored, it is a local problem. Check the following:

  • Make sure that there are no more than two junction boxes between the call station and the monitor,
  • Make sure that the connections in the junction box are correct, and that no wires are outside the dominoes,
  • Make sure that the V350 cables are run in a different conduit than the call station cable in order to avoid interference.
  • Make sure that they are electrical cables (if the distance is less than 80m => 0.5mm² minimum, if the distance is between 80 and 120m => 0.75mm² to 1,5mm² max.) and not telephone cables,

 

For other cases and if the device continues to have this problem, contact Somfy consumer service.

 

How can we help you?

If you haven't found the answer to your question, we invite you to request a support ticket. We will answer you as soon as possible.

Open a ticket My ticket